PINNACLE ® Hip Solutions is a modular cup system designed with a wide range of acetabular cup options, biological and mechanical fixation alternatives and advanced bearing technologies that allows surgeons the flexibility to choose intraoperatively from among the most advanced technologies available depending on their patients' individual …

The MobileLink Acetabular Cup System can be combined with modular offset and/or inclining casing/insert adapters (Face Changer). The adapters allow restoration of the anatomy in revision cases. ... Ullmark G, Sorensen J, Nilsson O. Analysis of bone formation on porous and calcium phosphate-coated acetabular cups: a randomised clinical [18F ...

The R3 delta Ceramic Acetabular System is a ceramic-on-ceramic hip prosthesis composed of modular components that include a R3 porous coated acetabular shell, a zirconia toughed alumina ceramic acetabular liner, a zirconia toughened alumina ceramic femoral head, and one of four titanium alloy femoral stems.

MODULAR CALCAR REAMER SHAFT 200147000: MODULAR CALCAR REAMER DISC, SMALL ... DUOFIX™ HA Coating combines POROCOAT™ Porous Coating, ... EMPHASYS™ Acetabular …

Background: Dual mobility (DM) has been proven to reduce dislocation risk after total hip arthroplasty (THA). In the last decade modular DM (modDM) constructs have been introduced to allow the use of DM …

Several 2-dimensional and 3-dimensional surfaces are available for cementless acetabular fixation. Plain radiographs are used to assess osseointegration; however, the radiographs are limited by their inability to capture the bone fixation process occurring over the 3-dimensional cup surface. In this cadaveric study, we compared the …

Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level BMD. Using a large head monoblock device does not appear to be associated with an adverse effect on the local bone environment when compared to a …

Aims: Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown …

Modular acetabular augments: composite void fillers. Orthopedics. 2005; 28(9):971–972. > Link Google Scholar; 14. Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004; (429):201–208. …

Methods. Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) …

The modular device was an independent predictor of radiolucent lines (odds ratio 19.1, P = .007). No cases underwent revision surgery for acetabular loosening. Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level …

The System is a comprehensive, press-fit stem for reconstruction of various defects. It is used with Biomet Type I Taper modular heads, compatible acetabular shells, liners and screws. Components are available in a variety of designs and size ranges intended for uncemented primary and revision procedures. Learn about how Arcos Modular helps to ...

The G7 Acetabular System is a modular system, designed to provide numerous options for surgeons and patients in one compatible system. It is modular in design including multiple variants of acetabular shells: a titanium alloy (ASTM F136) shell with an apical hole and plug, the outer surface of the shell is coated with Biomet's Porous Plasma

The cementless BiMobile Acetabular Cup is available with a TiCaP double coating. The TiCaP double coating combines the properties of a highly porous layer of pure titanium for primary fixation and calcium phosphate coating, which together provide optimal primary and secondary implant stability. 4, 5 A special macrostructure on the cup equator increases …

The findings on autopsy-retrieved HA-coated cementless femoral stems parallel those discussed for HA-coated acetabular components. Tonino et al 55 reported on five postmortem retrievals of proximally HA-coated Ti-alloy femoral stems at 3.3 to 6.2 years after implantation. All stems were well-fixed and showed proximal and distal …

The modern DM bearings were coated with a bilayer of porous titanium, with or without hydroxyapatite, instead of alumina as the acetabular coating, to optimize bone fixation . As a result, the decreased cup loosening renders the implant comparable to the fixed inserts used in the conventional THA [ 39 ].

ls. Questions/purposes We asked the following questions: (1) Is the risk of revision surgery for loosening, wear, or liner dissociation low with the second-generation acetabular …

PINNACLE Acetabular Cup System with GRIPTION Porous Coating: 10A† 4 Million Sales Worldwide 1.4% cumulative revision rate 20 years of clinical heritage 18% less likely to be revised Over 4 million PINNACLE Cups sold worldwide since its introduction.7 1.4%, 10 year cumulative revision rate for PINNACLE Acetabular Cup System (N=43,740),

In 2010, we started a randomized controlled trial (Kiernan et al. 2020) to evaluate the potential superiority of modular Background and purpose -Modular-neck hip stems have been identified with ...

From simple primary to complex revision arthroplasty, Zimmer Biomet's G7 ® Acetabular System is a modular system offering a comprehensive portfolio of shell, fixation and bearing options to establish a stable joint in THA. The simplicity, efficiency and performance of the platform is designed to address the distinct needs of individual patients, giving …

Redesigned modular broach handle and broach interface, redesigned neck trials and a new threaded stem inserter all in one tray. R3 Acetabular System Compatible with a wide range of advanced bearing options with a porous coating design, offering excellent primary stability 7-9 and flexible instrumentation.

Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage …

Additionally, osteoconductive coating, such as hydroxyapatite or alumina-reduced surface finish, did not improve peri-acetabular bone remodelling around modular cups. These data suggest that rigid acetabular fixation results in a loss of BMD in all zones over time and that this loss cannot be recovered by increasing the osteointegration ...

GRIPTION™ Porous Coating is specifically engineered to maintain mechanical integrity under shear, compression, torsion and tension force. ... EMPHASYS™ Acetabular Solutions, PINNACLE™ Acetabular Solutions ... MODULAR CALCAR REAMER SHAFT 200147000: MODULAR CALCAR REAMER DISC, SMALL 200148000:

The outer acetabular cup is manufactured from cobalt chrome alloy and coated with CP Ti, and hydroxylapatite. The cobalt chrome cups are manufactured from materials certified to ASTM Standard ASTM F1537. MDM Liner The MDM (Modular Dual Mobility) Liner is a highly polished modular liner with a Trident locking mechanism.

Conclusions: This second-generation modular titanium fiber-metal-coated acetabular component with screw fixation had no loosening, no liner dissociation, and a low rate of …

By assembling these augment and revision shells in surgery, a modular acetabular revision component roughly shaped according to the intra-operative acetabular bone deficiency could be obtained. ... The bispherical porous–coated augments used in this study was designed and manufactured independently by our team, and related domestic …

The Morscher press-fit cup is an uncemented, non-modular, flexible, porous-coated acetabular component. The cup is designed with a flattened pole geometry with bi-radial eccentricity, providing optimal press-fit fixation and achieving intrinsic primary stability without the use of additional screw fixation [10, 11].The porous surface is achieved by …

A total of 41 patients (41 hips) underwent THA using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January …

Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level BMD. Using a large head monoblock device does not appear to be associated with an adverse effect on the local bone environment when compared to a …